Iwalewale ni vakadikeva batabata ni cagi

Okosita 18, 2021

Vakararaba, after using the air-cooled chiller for a long period of time, some problems cannot be avoided. If there is a failure, we should carefully check the operating conditions of the various parts of the icula machine. The main points are to check the refrigeration system, electrical system, air system, and water system. To judge whether their homework is normal, the editor below will analyze the inspection methods in detail with you.

Air-cooled chiller

No. 1, refrigeration system

Check whether there are cracks, breakages, frosting and condensation in the various pipes of the refrigeration system; whether there is any friction between the refrigeration pipes of the air-cooled chiller, and the pipes and the shell, especially the welding of the refrigerant pipes If there is any leakage at the joint connection, if there will be oil stains at the leakage position, you can also use a clean soft cloth or soft paper to scrub the pipe welding joint and the joint connection.

 

iKarua ni, electrical system

Check whether the fuse of the chiller electrical system is blown, whether the insulation of the electrical wire is intact, whether the circuit board is cracked, whether the connection is loose, kei na so tale. In particular, whether the electrical connection is well-touched, and the wiring screws and connectors are easily loosened to cause poor touch.

iKatolu, ventilation system

Check whether the air filter, heat exchanger coils and fins are too dusty; whether the air inlet and outlet are dredged; whether the fan and fan blades work normally; whether the wind power is normal, whether the water system is normal, kei na so tale. .

  1. Mechanical water system

Check whether the water system is leaking; whether the water inlet and outlet are dredged; whether the chiller water pump works normally. Listen to the power on and listen to whether the compressor working sound of the air-cooled chiller is normal, whether there is abnormal sound, whether there is noise in the operation of electric fans, water pump, and whether the noise is too loud, kei na so tale. When the air-cooled chiller is working, the vibration is slight and the noise is small under normal conditions.

 

Kevaka e tiko eso na nomu taro ena moici ni icula,yalovinaka mo tarogi keitou,keitou na solia vei iko na veiqaravi vinaka duadua!

Kerei/Wekasomu 008618958305290

IWASEWASE KEI NA IVAKATAKILAKILA:
Buloqu , ,

O na taleitaka talega

  • iYoli Digitaki

    Misini veivakaukauwataki ni icula totolo
    Misini moici ni icula ni VNT (PET)
    Misini moici ni icula ni VVC
    Misini moici ni icula roka e vakarua

  • Veitaratara Vei Keimami

    Talevoni Veikauyaki:+86.18368497929
    Vakaraitaka vei keda: +86.18368497929
    Kerei Kerei: +86.18368497929
    Mataveilawa:www.yongjiangimm.com
    I-meli:yongjiangimm@gmail.com

  • Veiqaravi