Tuam Tshoj high Performance Injection molding cav tov

blog

» blog

chiller yuav phim nrog lub pwm thiab txhaj tshuaj molding tshuab

Lub Yim Hli Ntuj 18, 2021

Raws li peb yeej paub, chillers yog lug siv, thiab ib leeg yog lub laj kab txias ntawm cov pwm yas. yeej, most plastic mold production plants are indispensable for the chiller, Li ntawd, hnub no lub flyse yuav ua kom paub meej tias koj paub meej. Yuav xaiv ib tug suitable chiller nyob rau hauv cov ntau lawm ntawm molds. Tsis tas li ntawd, since injection molding machines are often used together with chillers, it is unavoidable to introduce them here.

First, how to choose a chiller

txias

Qhov tseeb, a mold is a heat exchanger. The heat is transferred from the molten plastic to the mold, and then from the mold to the circulating cooling medium-ice water. Only a small amount of heat enters the air and the pressure of the injection molding machine. template. As everyone knows, quite a few of the plastic molding cycles are used for cooling, sometimes accounting for more than 80% of the plastic molding cycle. Yog li ntawd, it is absolutely necessary to control the cooling time to a minimum. Piv txwv, pwm pwm yog feem ntau 20 vib nas this. If the water in the cooling tower is replaced by the ice water generated by the chiller, nws yuav shortened rau 16 vib nas this. Although it is more expensive to select and equip the chiller at the beginning, it can increase the output value by 20%, and can obtain great benefits in the long-term production.

Li ntawd,, how to choose ice water energy? From the above, we can know that it is related to the specific heat capacity of the molding material, the temperature and weight of the melt when the glue is melted, and the temperature when the finished product is demolded.

Feem ntau, the injection molding mold is cooled, and the ice water pressure is selected from 0.1 to 0.2Mpa to satisfy the request. The microcomputer full-function chiller can satisfy this request. When the pressure request is higher than 0.2Mpa, another plan is required to facilitate the selection of the corresponding pressure. Qhov no txias water pump in order to meet the needs of the system water supply.

The connection table between flow and pipe diameter:

How to match the chiller with plastic molds and injection molding machines?

Tus qauv rau calculating cov dej khov zog yuav tsum tau los ntawm ib tug pwm yog: q=w×c×t×s

qauv: q is the required ice water energy kcal/h;

W is the plastic raw material weight kg/h;

C is the specific heat of plastic raw materials kcal/kg℃;

T is the temperature difference ℃ between the melt temperature and the finished product demoulding;

s is the safety factor (usually 1.35—2.0). Thaum ib lub tshuab xwb matched, Tus nqi me me yog feem ntau xaiv, thiab tus nqi loj yog siv thaum ib chiller yog matched nrog ntau molds. Piv txwv, Thaum ib tug cua txias yog xaiv, s is also It should be appropriately larger.

Piv txwv: a mold produces pp finished products, and the output value per hour is about 50kg. What is the cooling requirement? What size water chiller should be equipped with? q=50×0.48×200×1.35=6480 (kcal/h); cooling capacity of 6480kcal/h per hour is required, and ls203s chiller can be used.

In the process of selecting chillers in practice, it is difficult to obtain well-compared data. Raws li peb lub xyoo dhau los npaj thiab txhawb kev muag khoom, t=200℃, which is an average value of many commonly used products after years of calculation.

Yog tias muaj ib txoj kab glue uas txuas rau lub pwm, the energy of the hot glue lane should also be included in the calculation of the cooling capacity. Feem ntau, the hot glue lane is in kw, and the unit should be converted to kcal/h when calculating, 1kw=860kcal/h. Yog hais tias cov dej mov rau lub Hoobkas txaus, qhov kub tshaj plaws yog qhov kub tshaj plaws, thiab tus nqi tsawg tshaj 6 xyoo, there is no need to use a chiller at this moment. This is generally impractical unless the factory can be located near a large lake with a low water temperature. The other is to use urban areas. Deep well water supply meets the needs of temperature and flow, Tiam sis tus nqi feem ntau yog ib yam nkaus thiab. This method can be used for test equipment, but for factories, it is impractical to do so.

  1. Ice water temperature difference

The temperature of the plastic mold cooling fluid (dej khov) generally changes greatly due to the processing materials and the shape of the finished product. Piv txwv, for polystyrene thin-walled beakers, the mold requires the ice water temperature to be below 0°C; in most other cases, The temperature of the ice water requested by the mold is above 5℃, the microcomputer full-function chiller can provide ice water above 5℃, and the low-temperature intelligent temperature control chiller can satisfy the request below 5℃ and below 0℃.

The temperature difference of the ice water at the entrance and exit of the plastic mold is often set according to the requirements of the finished product. Ntau zaus, the temperature difference of 3-5°C is the most ideal, but sometimes the temperature difference is also required to be 1-2°C. The smaller the temperature difference, it means that the same amount of heat is taken out, the larger the flow of ice water is needed, and vice versa. Piv txwv: when the temperature difference is 5°C, the flow rate needs 60l, and when the temperature difference is 2°C, the flow rate needs 150l.

  1. Ice water flow

The flow of ice water required for a plastic mold is directly related to the heat to be taken away by the mold and the temperature difference between the ice water in and out of the mold. Piv txwv: To take the heat of 6480kcal/h away from the mold, if the temperature difference is 3℃, what is the minimum flow rate required? Ice water flow q=6480÷3÷60=36 (l/min).

Plaub, the theory of ice water quality

The softening of water is also a question that cannot be ignored in the process of using the chiller. The ph value of water also needs to be continuously observed. It is best that the ph value should be equal to 7, and the ph value greater than 7 will cause terrible corrosion. If the method is not adopted, fouling will form in the evaporator and the mold, which will act as heat insulation. When severe, the energy conversion effect will be reduced by 30%. Obviously this requires thinking about the softening of hard water. The most effective way is to equip an electronic hard water softener in the system. Such a softener is planned to be manufactured based on the principle of exchange. Depending on the flow rate, different standard softeners can be equipped, and they can be directly connected to the circulating water pipeline. Feem ntau, the cost of installing a water treatment softener will not be too high. It can also participate in a certain amount of deduction in the circulating system for a certain period of time. Scale agent.

Five, ice water machine flow and pressure

Feem ntau, the injection molding mold is cooled, and the ice water pressure can be selected from 0.1 to 0.2mpa, and the request can be satisfied, and the microcomputer full-function chiller can satisfy this request. When the pressure request is higher than 0.2mpa, another plan is required to facilitate the selection of the corresponding pressure From the water pump to meet the needs of the system water supply.

  1. Cooling of hydraulic oil and barrel feeding section

Feem ntau, the hydraulic oil and barrel feeding section use cooling water tower water to cool, because this is not only the best way, it is cost-effective, but also very economical. Unless there are specific requirements for its temperature, ice water can be used for it. Cool down.

VII. Insulation of ice water pipes

The ice water pipeline must be insulated, because the pipeline insulation can not only prevent the severe loss of cold capacity, but also prevent the condensation formed on the outer wall of the pipe. Piv txwv: the temperature of ice water is 10℃, the ambient temperature is 30℃, the heat radiation of a 25-meter-long metal pipe with a surface area of ​​25m2 can reach 750kcal/h, which is almost 10% of the cooling capacity of a 3hp compressor, 5hp The compressor produces 6% of the cooling capacity.

The connection between the chiller and the plastic mold is generally selected to be connected with a reinforced hose. Since such a hose has the function of heat insulation, but the length exceeds 5m, it is necessary to consider appropriate heat preservation and heat insulation. In the application of the chiller, it is closely related to another equipment, uas yog, the injection molding machine. Since it is so relevant, how to choose an injection molding machine, let us introduce you:

How to choose a chiller and an injection molding machine?

The domestic vertical and horizontal injection molding machines are matched when the cooling water condensation temperature of the water-cooled chiller is below 35 degrees (the condensation temperature of the air-cooled chiller is below 43 degrees) when the domestic vertical and horizontal injection molding machines are used at normal ambient temperature.

  1. The first method:

The 1hp water-cooled chiller can be equipped with an 80-ton clamping force injection molding machine with a temperature control of 5-10 degrees;

The 1hp water-cooled chiller can be equipped with a 100-ton clamping force injection molding machine with a temperature control of 10-15 degrees;

The 1hp water-cooled chiller can be equipped with a 120-ton clamping force injection molding machine with a temperature control of 15-20 degrees;

(The matching of the air-cooled chiller is 0.8 times that of the water-cooled chiller, uas yog, the 1HP air-cooled chiller can be equipped with a 64-ton injection molding machine with a clamping force. The temperature is controlled at 5-10 degrees.)

  1. The second method:

The 1HP water-cooled chiller can be equipped with an injection molding machine with a single injection volume of 10QZ, and the temperature is controlled at 5-10 degrees.

Injection volume 1QZ=28.5g

The above formula is the result summarized by the thoughts. In addition to using the above formula, the salesperson should consider the actual situation and select the appropriate chiller.

  1. Matching of chiller and cooling tower:

According to previous practice, a 1HP chiller needs a 1.2-ton cooling water tower to take away the heat generated by the chiller.

Yog koj muaj lus nug txog txhaj,plz feel free to ask us,Peb yuav muab kev pab zoo tshaj rau koj!

Yam Tsis Muaj Zog/Wechat 008618958305290

QEB THIAB KEV PHEEJ YIG:
blog ,

Tej zaum koj nyiam thiab

» Pwm pwm
  • Cov Khoom Tshwj Xeeb

    Siab ceev ceev pwm molding cav tov
    PET injection molding cav tov
    PVC injection molding cav tov
    Ob npaug ntawm cov cav tov uas muaj cav tov

  • Hu rau Peb

    txawb:+86.18368497929
    Weatch: +86.18368497929
    Dabtsi: +86.18368497929
    Web site:www.yongjiangimm.com
    E-mail:yongjiangimm@gmail.com